• Institute
  • AC to DC Power Supplies / SMPS – 130w-300w

    Specifications

    MODEL                                    : PS2410A

    INPUT
    I/P                                        : 230V AC, 1-Ph
    Frequency                              : 47-63Hz
    Range                                    : 180-270V AC
    Fuse Protection.                     : Yes
    I/P MOV                                : Yes
    Soft Start                             : Yes
    Inrush current                       : 46A@230V AC
    AC Current
    Leakage current                     : <5mA@230V AC

    OUTPUT
    Nominal Voltage                      : 24V DC
    Voltage Range                        : 24-28V
    Rated  Current                       : 10A
    Line Regulation                       : +/- 1%
    Load Regulation                      : +/- 1%
    Ripple Max                                      : +/- 1% (P-P)
    Noise Max                              : +/- 1% (P-P)
    Protections                          
    : a) Overload Protection auto recovery type:102-105%
    b) Short circuit protection auto recovery type:Yes
    c) Over Voltage Protection Latching type:105-110%
    Current Limit.                       : Yes
    Start up time                        : 2.8sec
    Hold up time                          : 28ms@230V AC

    ENVIRONMENTAL 
    Operating temperature upto 500 C.
    Humidity                               : < 95% Rh
    IP 21  Protection

    GENERAL
    Isolation                              : Input to Output – 1.5KV
    Input to Earth – 1.5KV
    Output to Earth- 500V
    MTBF                                  : 50K Hrs to MIL
    Efficiency                           : 80%

    INDICATIONS LED           : a) Input OK
    b) Output OK
    c) Output OVP

    MECHANICAL
    Dimension                                 : 195W X 130D X 95H mm
    Cooling type                             : Fan cooled – exhaust ??
    Weight                                    : 1.4 Kgs

    OPTIONAL
    Redundancy by external diode.  
    Potential Free Contact – Alarm contact
    Programmable by external signal – voltage & current
    Remote ON/OFF

    With Digital Voltmeter & Currenmeter

    2 Years Warranty

    Specification subject to change as per our continuous developments

    For inquiries / customized requirements Contact Us on kbelectronics@gmail.com